View larger
RASP5-5401A31-512R100S1 198799 Y7-198799 EATON ELECTRIC RASP5-5401A31-512R100S1
RASP5-5401A31-512R100S1
198799
Y7-198799
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Featuring a rugged distributed design, the Eaton Moeller RASP5-5401A31-512R100S1 brings efficient frequency conversion directly to the machine level. Decentralized drives eliminate long motor cables, minimize electromagnetic interference, and streamline system installation in modern automated facilities. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
UL approval
IEC/EN 61800-5-1
RoHS
Features & Functions
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect
Parameterization: Keypad
Parameterization: Fieldbus
Control unit
Breaking resistance
Key switch position HAND
PTC thermistor monitoring
Selector switch (Positions: REV - OFF - FWD)
PC connection
Braking resistance
IGBT inverter
Key switch position OFF/RESET
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Internal DC link
Manual override switch
Thermo-click with safe isolation
1 potentiometer speed
For actuation of motors with mechanical brake
4-quadrant operation possible
3 fixed speeds
General
IP65
AS-Interface profile cable: S-7.4 for 31 modules
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, On-delay
PM and LSPM motors
Sensorless vector control (SLV)
U/f control
Synchronous reluctance motors
At 40 °C
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length