View larger
RASP5-5401A31-5120100S1 198797 Y7-198797 EATON ELECTRIC RASP5-5401A31-5120100S1
RASP5-5401A31-5120100S1
198797
Y7-198797
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Variable frequency drive unit RASP5-5401A31-5120100S1 by Eaton Moeller modulates AC motor performance to provide flexible speed control and protect connected mechanical assets. Plant engineers install these electronics to streamline complex production cycles and reduce overall electrical power consumption.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
RoHS
CE
UL 61800-5-1
Features & Functions
Parameterization: Fieldbus
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
PC connection
Key switch position AUTO
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
Breaking resistance
Four fixed speeds
Control unit
IGBT inverter
Selector switch (Positions: REV - OFF - FWD)
Key switch position OFF/RESET
PTC thermistor monitoring
Braking resistance
Brake chopper with braking resistance for dynamic braking
4-quadrant operation possible
General
NEMA 12
ASI
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
Sensorless vector control (SLV)
U/f control
BLDC motors
PM and LSPM motors
For 60 s every 600 s
400 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length