View larger
RASP5-5401A31-412R010S1 198825 Y7-198825 EATON ELECTRIC RASP5-5401A31-412R010S1
RASP5-5401A31-412R010S1
198825
Y7-198825
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The RASP5-5401A31-412R010S1 Eaton Electric drive unit provides robust, decentralized motor management for complex three-phase industrial applications. Decentralized drives are typically mounted directly onto machinery or near actuators to streamline wiring layouts and improve operational control in modular manufacturing systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
IEC/EN 61800-5-1
CE
UL approval
Features & Functions
Parameterization: Keypad
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect
Parameterization: Fieldbus
Control unit
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
Key switch position OFF/RESET
Key switch position HAND
Internal DC link
PTC thermistor monitoring
Key switch position AUTO
IGBT inverter
Manual override switch
Thermo-click with safe isolation
3 fixed speeds
STO (Safe Torque Off)
For actuation of motors with mechanical brake
General
NEMA 12
ASI
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
BLDC motors
Synchronous reluctance motors
U/f control
PM and LSPM motors
For 60 s every 600 s
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length