View larger
RASP5-5401A31-4120110S1 198813 Y7-198813 EATON ELECTRIC RASP5-5401A31-4120110S1
RASP5-5401A31-4120110S1
198813
Y7-198813
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Regulate electric motor velocity and optimize system performance with the Eaton Moeller RASP5-5401A31-4120110S1 frequency converter. Devices of this type manage the power delivered to AC motors, allowing for smooth acceleration, deceleration, and energy conservation in complex industrial production lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
CE
RoHS
UL 61800-5-1
Features & Functions
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Selector switch (Positions: REV - OFF - FWD)
Breaking resistance
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Braking resistance
Thermo-click with safe isolation
Four fixed speeds
Internal DC link
IGBT inverter
Key switch position OFF/RESET
PTC thermistor monitoring
Key switch position HAND
Control unit
4-quadrant operation possible
STO (Safe Torque Off)
For actuation of motors with mechanical brake
General
NEMA 12
ASI
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Phase-earthed AC supply systems are not permitted.
AC voltage
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
BLDC motors
Synchronous reluctance motors
Sensorless vector control (SLV)
PM and LSPM motors
At 40 °C
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
AC voltage
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length