RASP5-5400A31-412R100S1 198820 Y7-198820 EATON ELECTRIC RASP5-5400A31-412R100S1
RASP5-5400A31-412R100S1
198820
Y7-198820
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-5400A31-412R100S1 is a frequency converter used in automated production lines to govern alternating current motor velocity. Such electronic controllers allow operators to precisely tune motor operational profiles, protecting mechanical drive trains and enhancing system reliability.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
CE
RoHS
UL approval
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Braking resistance
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Control unit
Manual override switch
Thermo-click with safe isolation
PTC thermistor monitoring
Internal DC link
PC connection
Key switch position OFF/RESET
Selector switch (Positions: REV - OFF - FWD)
Breaking resistance
IGBT inverter
1 potentiometer speed
4-quadrant operation possible
Brake chopper with braking resistance for dynamic braking
General
NEMA 12
ASI
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, On-delay
U/f control
Synchronous reluctance motors
BLDC motors
Sensorless vector control (SLV)
For 60 s every 600 s
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length