View larger
RASP5-5400A31-4120000S1 198800 Y7-198800 EATON ELECTRIC RASP5-5400A31-4120000S1
RASP5-5400A31-4120000S1
198800
Y7-198800
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
RASP5-5400A31-4120000S1 from Eaton Moeller serves as a decentralized motor starter and frequency controller for modular machine layouts. This component combines switching and drive technology to simplify wiring and control tasks directly on industrial production equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 5.6 A
- Power consumption: 58 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 0
- Number of analogue inputs: 0
- Number of digital outputs: 0
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
RoHS
UL 61800-5-1
CE
UL approval
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: drivesConnect
Parameterization: Keypad
Thermo-click with safe isolation
Four fixed speeds
Control unit
Key switch position HAND
PC connection
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Internal DC link
Key switch position OFF/RESET
IGBT inverter
Selector switch (Positions: REV - OFF - FWD)
General
IP65
AS-Interface profile cable: S-7.4 for 31 modules
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
PM and LSPM motors
U/f control
Sensorless vector control (SLV)
Synchronous reluctance motors
For 60 s every 600 s
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length