View larger
RASP5-4422PNT-412R000S1 198982 Y7-198982 EATON ELECTRIC RASP5-4422PNT-412R000S1
RASP5-4422PNT-412R000S1
198982
Y7-198982
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part RASP5-4422PNT-412R000S1 operates as an advanced motor control and frequency conversion unit designed for decentralized automation architectures. Industrial facilities integrate such devices near driven machinery to streamline wiring, control motor speeds efficiently, and interface directly with local sensor networks.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
RoHS
UL approval
UL 61800-5-1
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Selector switch (Positions: REV - OFF - FWD)
Key switch position AUTO
PTC thermistor monitoring
Manual override switch
Key switch position HAND
Control unit
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Internal DC link
PC connection
IGBT inverter
Thermo-click with safe isolation
2 Actuator outputs
3 fixed speeds
For actuation of motors with mechanical brake
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, On-delay
BLDC motors
U/f control
Synchronous reluctance motors
PM and LSPM motors
For 60 s every 600 s
400 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
230/277 V AC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length