View larger
RASP5-4422PNT-4120110S1 198978 Y7-198978 EATON ELECTRIC RASP5-4422PNT-4120110S1
RASP5-4422PNT-4120110S1
198978
Y7-198978
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-4422PNT-4120110S1 operates as an advanced variable frequency drive engineered to regulate motor speed and torque in demanding production environments. Such drives provide precise frequency modulation and process optimization across multi-phase electrical setups, enhancing overall machinery efficiency and operational safety. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲Delivery program
480 V AC, 3-phase
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
optional: 4 sensor inputs with M12-Y adapter for switchover to creep speed
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on the device and via PROFINET
with AUTO - OFF/RESET - HAND key switches
3 fixed speeds and 1 potentiometer speed
can be switched over from U/f to (vector) speed control
with selector switch REV - OFF - FWD
optional: Faster stop if external 24 V fails
Fieldbus
drivesConnect
drivesConnect mobile (App)
integrated brake chopper with braking resistance for dynamic braking
Technical data
UL 61800-5-1
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
IEC/EN 50178 %
C2 ≤ 5 m
C3 ≤ 25 m m
IEC/EN 60068-2-27 g
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
NEMA12
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
at 40 °C
adjustable 4 - 32 kHz
sensorless vector control (SLV)
PM and LSPM motors
Synchronous reluctance motors
BLDC motors
adjustable A
without fan
with braking resistance
(max. 6 A for 120 ms) A
Specification: S-7.4
Number of slave addresses: 31