View larger
RASP5-4422EIP-412R100S1 198890 Y7-198890 EATON ELECTRIC RASP5-4422EIP-412R100S1
RASP5-4422EIP-412R100S1
198890
Y7-198890
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-4422EIP-412R100S1 is a specialized electronic drive unit integrated into complex machinery for localized motion control and motor regulation. Decentralized drive solutions simplify cabling and improve operational responsiveness across distributed industrial floors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
RoHS
IEC/EN 61800-5-1
UL approval
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Thermo-click with safe isolation
Internal DC link
2 Actuator outputs
Key switch position HAND
PC connection
IGBT inverter
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
Braking resistance
Breaking resistance
Key switch position AUTO
Key switch position OFF/RESET
PTC thermistor monitoring
Manual override switch
1 potentiometer speed
Brake chopper with braking resistance for dynamic braking
3 fixed speeds
For actuation of motors with mechanical brake
General
IP65
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, Off-delay
Synchronous reluctance motors
PM and LSPM motors
BLDC motors
Sensorless vector control (SLV)
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
230/277 V AC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length