View larger
RASP5-4421PNT-412R010S1
198989
Y7-198989
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Rapid Link Speed controller |
| Catalog Number | 198989 |
| Model Code | RASP5-4421PNT-412R010S1 |
| EAN | 4015081970476 |
| Product Length/Depth | 157 mm |
| Product Height | 270 mm |
| Product Width | 220 mm |
| Product Weight | 3.62 kg |
| Certifications | CE IEC/EN 61800-5-1 UL approval RoHS UL 61800-5-1 |
| Catalog Notes |
|
| Mounting position | Vertical |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft |
| Vibration | Resistance: 6 Hz, Amplitude 0.15 mm Resistance: 57 Hz, Amplitude transition frequency on acceleration Resistance: According to IEC/EN 60068-2-6 Resistance: 10 - 150 Hz, Oscillation frequency |
| Braking current | ≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake |
| Braking torque | Adjustable to 100 % (I/Ie), DC - Main circuit ≤ 30 % (I/Ie) |
| Braking voltage | 280/207 V DC -15 % / +10 %, Actuator for external motor brake |
| Cable length | C3 ≤ 25 m, maximum motor cable length C2 ≤ 5 m, maximum motor cable length C1 ≤ 1 m, maximum motor cable length |
| Altitude | Max. 2000 m Above 1000 m with 1 % performance reduction per 100 m |
| Ambient operating temperature - max | 40 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient operating temperature - min | -10 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | < 95 %, no condensation In accordance with IEC/EN 50178 |
| Communication interface | PROFINET, optional |
| Connection | Plug type: HAN Q4/2 |
| Interfaces | Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA Number of slave addresses: 31 (AS-Interface®) Specification: S-7.4 (AS-Interface®) |
| Rated control voltage (Uc) | 180/207 V DC (external brake 50/60 Hz) 24 V DC (-15 %/+20 %, external via AS-Interface® plug) |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Features | Parameterization: drivesConnect mobile (App) Parameterization: Fieldbus Parameterization: Keypad Parameterization: drivesConnect |
| Fitted with: | Internal DC link IGBT inverter Key switch position AUTO Key switch position OFF/RESET 2 Actuator outputs Thermo-click with safe isolation Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Manual override switch PC connection Key switch position HAND Control unit Selector switch (Positions: REV - OFF - FWD) PTC thermistor monitoring |
| Functions | STO (Safe Torque Off) For actuation of motors with mechanical brake 3 fixed speeds 1 potentiometer speed |
| Degree of protection | NEMA 12 IP65 |
| Electromagnetic compatibility | 1st and 2nd environments (according to EN 61800-3) |
| Overvoltage category | III |
| Product category | Speed controller |
| Protocol | PROFINET IO |
| Radio interference class | C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. C1: for conducted emissions only |
| Rated impulse withstand voltage (Uimp) | 2000 V |
| System configuration type | AC voltage Phase-earthed AC supply systems are not permitted. Center-point earthed star network (TN-S network) |
| Current limitation | Adjustable, motor, main circuit 0.4 - 4.3 A, motor, main circuit |
| Delay time | < 10 ms, On-delay < 10 ms, Off-delay |
| Efficiency | 98 % (η) |
| Heat dissipation at current/speed | 32.3 W at 25% current and 0% speed 33.2 W at 25% current and 50% speed 35.2 W at 50% current and 90% speed 36.2 W at 50% current and 0% speed 37.6 W at 50% current and 50% speed 46.3 W at 100% current and 90% speed 48.7 W at 100% current and 0% speed 48.7 W at 100% current and 50% speed |
| Input current ILN at 150% overload | 4.1 A |
| Leakage current at ground IPE - max | 3.5 mA |
| Mains current distortion | 120 % |
| Mains switch-on frequency | Maximum of one time every 60 seconds |
| Mains voltage - max | 480 V |
| Mains voltage - min | 380 V |
| Mains voltage tolerance | 380 - 480 V (-10 %/+10 %, at 50/60 Hz) |
| Operating mode | PM and LSPM motors BLDC motors Synchronous reluctance motors U/f control Sensorless vector control (SLV) |
| Output frequency - max | 500 Hz |
| Output frequency - min | 0 Hz |
| Overload current | At 40 °C For 60 s every 600 s |
| Overload current IL at 150% overload | 6.5 A |
| Rated frequency - max | 66 Hz |
| Rated frequency - min | 45 Hz |
| Rated operational current (Ie) | 4.3 A at 150% overload (at an operating frequency of 8 kHz and an ambient air temperature of +40 °C) |
| Rated operational power at 380/400 V, 50 Hz, 3-phase | 1.5 kW |
| Rated operational voltage | 400 V AC, 3-phase 480 V AC, 3-phase |
| Resolution | 0.1 Hz (Frequency resolution, setpoint value) |
| Starting current - max | 200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section |
| Supply frequency | 50/60 Hz |
| Switching frequency | 8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit |
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 2 HP |
| Rated conditional short-circuit current (Iq) | 10 kA |
| Short-circuit protection (external output circuits) | Type 1 coordination via the power bus' feeder unit, Main circuit |
| Feature Name | Feature Value |
|---|---|
| Mains voltage (EF006780) | 380 V |
| Mains frequency (EF006783) | 50/60 Hz |
| Number of phases input (EF007117) | 3 |
| Number of phases output (EF006998) | 3 |
| Max. output frequency (EF007350) | 500 Hz |
| Max. output voltage (EF009560) | 500 V |
| Nominal output current I2N (EF009561) | 4.3 A |
| Max. output at quadratic load at rated output voltage (EF007366) | 1.5 kW |
| Max. output at linear load at rated output voltage (EF007364) | 1.5 kW |
| Power consumption (EF000346) | 46 W |
| Relative symmetric net frequency tolerance (EF007454) | 10 % |
| Relative symmetric net voltage tolerance (EF007453) | 10 % |
| Number of analogue outputs (EF001995) | 0 |
| Number of analogue inputs (EF001994) | 0 |
| Number of digital outputs (EF001993) | 2 |
| Number of digital inputs (EF001992) | 4 |
| With control element (EF001538) | Yes |
| Application in industrial area permitted (EF007294) | Yes |
| Application in domestic- and commercial area permitted (EF007295) | Yes |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for PROFINET IO (EF007525) | Yes |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for BACnet (EF011944) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 2 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 1 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces other (EF003027) | 0 |
| With optical interface (EF003028) | No |
| With PC connection (EF006107) | Yes |
| Integrated breaking resistance (EF007293) | No |
| 4-quadrant operation possible (EF006803) | No |
| Type of converter (EF006978) | U converter |
| Degree of protection (IP) (EF005474) | IP65 |
| Degree of protection (NEMA) (EF011959) | 12 |
| Height (EF000040) | 270 mm |
| Width (EF000008) | 220 mm |
| Depth (EF000049) | 157 mm |