View larger
RASP5-4421PNT-4120110S1 198977 Y7-198977 EATON ELECTRIC RASP5-4421PNT-4120110S1
RASP5-4421PNT-4120110S1
198977
Y7-198977
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered by Eaton Moeller, the RASP5-4421PNT-4120110S1 frequency converter manages power distribution and speed scaling for industrial electric drives.
These units allow facilities to dynamically alter motor speeds, reducing mechanical wear and optimizing power consumption across complex manufacturing and material handling workflows. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
CE
IEC/EN 61800-5-1
UL approval
Features & Functions
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Braking resistance
Thermo-click with safe isolation
2 Actuator outputs
Internal DC link
PC connection
Breaking resistance
Key switch position AUTO
Selector switch (Positions: REV - OFF - FWD)
Control unit
Key switch position OFF/RESET
IGBT inverter
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
PTC thermistor monitoring
STO (Safe Torque Off)
For actuation of motors with mechanical brake
1 potentiometer speed
4-quadrant operation possible
Brake chopper with braking resistance for dynamic braking
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, Off-delay
BLDC motors
PM and LSPM motors
Synchronous reluctance motors
U/f control
At 40 °C
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length