View larger
RASP5-4421PNT-4120010S1 198973 Y7-198973 EATON ELECTRIC RASP5-4421PNT-4120010S1
RASP5-4421PNT-4120010S1
198973
Y7-198973
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Decentralized motor management is streamlined using the Eaton Moeller RASP5-4421PNT-4120010S1 integrated drive system, built to mount directly onto machine frames near the driven load. These modular units combine switching and frequency conversion to reduce cabinet space requirements and simplify wiring topologies in modern factory environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
UL approval
RoHS
UL 61800-5-1
Features & Functions
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Key switch position AUTO
Key switch position OFF/RESET
IGBT inverter
PTC thermistor monitoring
Internal DC link
Selector switch (Positions: REV - OFF - FWD)
PC connection
Thermo-click with safe isolation
2 Actuator outputs
Control unit
Key switch position HAND
STO (Safe Torque Off)
For actuation of motors with mechanical brake
3 fixed speeds
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, Off-delay
Sensorless vector control (SLV)
U/f control
BLDC motors
Synchronous reluctance motors
For 60 s every 600 s
400 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length