View larger
RASP5-4421EIP-412R010S1 198893 Y7-198893 EATON ELECTRIC RASP5-4421EIP-412R010S1
RASP5-4421EIP-412R010S1
198893
Y7-198893
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for decentralized automation networks, this Eaton Moeller speed controller integrates seamlessly with industrial fieldbus systems to govern motor dynamics. Speed controllers are widely implemented across material handling lines to maintain synchronized mechanical pacing.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Rapid Link Speed controller
- Catalog Number: 198893
- Model Code: RASP5-4421EIP-412R010S1
- EAN: 4015081969517
- Product Length/Depth: 157 mm
- Product Height: 270 mm
- Product Width: 220 mm
- Product Weight: 3.6 kg
- Certifications: CE IEC/EN 61800-5-1 RoHS UL 61800-5-1 UL approval
- Degree of protection: IP65 NEMA 12
- Electromagnetic compatibility: 1st and 2nd environments (according to EN 61800-3)
- Overvoltage category: III
- Product category: Speed controller
- Product category: Speed controller
- Protocol: EtherNet/IP
- Rated impulse withstand voltage (Uimp): 2000 V
More info
▲General specifications
| Product Name | Eaton Rapid Link Speed controller |
| Catalog Number | 198893 |
| Model Code | RASP5-4421EIP-412R010S1 |
| EAN | 4015081969517 |
| Product Length/Depth | 157 mm |
| Product Height | 270 mm |
| Product Width | 220 mm |
| Product Weight | 3.6 kg |
| Certifications | CE IEC/EN 61800-5-1 RoHS UL 61800-5-1 UL approval |
| Catalog Notes |
|
Features & Functions
| Features | Parameterization: Keypad Parameterization: Fieldbus Parameterization: drivesConnect Parameterization: drivesConnect mobile (App) |
| Fitted with: | Key switch position AUTO 2 Actuator outputs Manual override switch Selector switch (Positions: REV - OFF - FWD) Control unit PTC thermistor monitoring Internal DC link PC connection IGBT inverter Key switch position OFF/RESET Key switch position HAND Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Thermo-click with safe isolation |
| Functions | 1 potentiometer speed STO (Safe Torque Off) For actuation of motors with mechanical brake 3 fixed speeds |
General information
| Degree of protection | IP65 NEMA 12 |
| Electromagnetic compatibility | 1st and 2nd environments (according to EN 61800-3) |
| Overvoltage category | III |
| Product category | Speed controller |
| Product category | Speed controller |
| Protocol | EtherNet/IP |
| Radio interference class | C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. C1: for conducted emissions only |
| Rated impulse withstand voltage (Uimp) | 2000 V |
| System configuration type | Phase-earthed AC supply systems are not permitted. Center-point earthed star network (TN-S network) AC voltage |
Ambient conditions, mechanical
| Mounting position | Vertical |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft |
| Vibration | Resistance: According to IEC/EN 60068-2-6 Resistance: 10 - 150 Hz, Oscillation frequency Resistance: 57 Hz, Amplitude transition frequency on acceleration Resistance: 6 Hz, Amplitude 0.15 mm |
Climatic environmental conditions
| Altitude | Max. 2000 m Above 1000 m with 1 % performance reduction per 100 m |
| Ambient operating temperature - min | -10 °C |
| Ambient operating temperature - max | 40 °C |
| Ambient storage temperature - min | -40 °C |
| Ambient storage temperature - max | 70 °C |
| Climatic proofing | < 95 %, no condensation In accordance with IEC/EN 50178 |
Main circuit
| Current limitation | Adjustable, motor, main circuit 0.4 - 4.3 A, motor, main circuit |
| Delay time | < 10 ms, On-delay < 10 ms, Off-delay |
| Efficiency | 98 % (η) |
| Heat dissipation at current/speed | 32.3 W at 25% current and 0% speed 33.2 W at 25% current and 50% speed 35.2 W at 50% current and 90% speed 36.2 W at 50% current and 0% speed 37.6 W at 50% current and 50% speed 46.3 W at 100% current and 90% speed 48.7 W at 100% current and 0% speed 48.7 W at 100% current and 50% speed |
| Input current ILN at 150% overload | 4.1 A |
| Leakage current at ground IPE - max | 3.5 mA |
| Mains current distortion | 120 % |
| Mains switch-on frequency | Maximum of one time every 60 seconds |
| Mains voltage - max | 480 V |
| Mains voltage - min | 380 V |
| Mains voltage tolerance | 380 - 480 V (-10 %/+10 %, at 50/60 Hz) |
| Operating mode | U/f control Synchronous reluctance motors Sensorless vector control (SLV) BLDC motors PM and LSPM motors |
| Output frequency - max | 500 Hz |
| Output frequency - min | 0 Hz |
| Overload current | For 60 s every 600 s At 40 °C |
| Overload current IL at 150% overload | 6.5 A |
| Rated frequency - max | 66 Hz |
| Rated frequency - min | 45 Hz |
| Rated operational current (Ie) | 4.3 A at 150% overload (at an operating frequency of 8 kHz and an ambient air temperature of +40 °C) |
| Rated operational power at 380/400 V, 50 Hz, 3-phase | 0.75 kW |
| Rated operational voltage | 480 V AC, 3-phase 400 V AC, 3-phase |
| Resolution | 0.1 Hz (Frequency resolution, setpoint value) |
| Starting current - max | 200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section |
| Supply frequency | 50/60 Hz |
| Switching frequency | 8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit |
Motor rating
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 2 HP |
Braking function
| Braking current | ≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake |
| Braking torque | ≤ 30 % (I/Ie) Adjustable to 100 % (I/Ie), DC - Main circuit |
| Braking voltage | 280/207 V DC -15 % / +10 %, Actuator for external motor brake |
Short-circuit rating
| Rated conditional short-circuit current (Iq) | 10 kA |
| Short-circuit protection (external output circuits) | Type 1 coordination via the power bus' feeder unit, Main circuit |
Control circuit
| Rated control voltage (Uc) | 180/207 V DC (external brake 50/60 Hz) 24 V DC (-15 %/+20 %, external via AS-Interface® plug) |
Communication
| Communication interface | Ethernet IP, built in |
| Connection | Plug type: HAN Q4/2 |
| Interfaces | Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA Number of slave addresses: 31 (AS-Interface®) Specification: S-7.4 (AS-Interface®) |
Cable
| Cable length | C1 ≤ 1 m, maximum motor cable length C2 ≤ 5 m, maximum motor cable length C3 ≤ 25 m, maximum motor cable length |
Design verification
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |