View larger
RASP5-4420PNT-4120010S1 198972 Y7-198972 EATON ELECTRIC RASP5-4420PNT-4120010S1
RASP5-4420PNT-4120010S1
198972
Y7-198972
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A networked motor starter manages power distribution and operational commands for automated industrial drives, minimizing downtime in continuous production lines. This Eaton Moeller RASP5-4420PNT-4120010S1 device combines integrated frequency control with robust fieldbus communication.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
CE
UL approval
IEC/EN 61800-5-1
Features & Functions
Parameterization: drivesConnect
Parameterization: Keypad
Parameterization: Fieldbus
Key switch position HAND
IGBT inverter
PC connection
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
PTC thermistor monitoring
Thermo-click with safe isolation
Selector switch (Positions: REV - OFF - FWD)
2 Actuator outputs
Control unit
Internal DC link
STO (Safe Torque Off)
1 potentiometer speed
General
NEMA 12
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, Off-delay
Synchronous reluctance motors
Sensorless vector control (SLV)
BLDC motors
PM and LSPM motors
At 40 °C
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Number of slave addresses: 31 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length