View larger
RASP5-4420EIP-412R110S1 198896 Y7-198896 EATON ELECTRIC RASP5-4420EIP-412R110S1
RASP5-4420EIP-412R110S1
198896
Y7-198896
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-4420EIP-412R110S1 is a frequency inverter built for decentralized motor management within automated industrial systems. Such drives enable local speed regulation and communication integration directly on or near the driven machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 4.3 A
- Power consumption: 46 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 0
- Number of analogue inputs: 0
- Number of digital outputs: 2
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
CE
UL approval
IEC/EN 61800-5-1
RoHS
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Parameterization: Fieldbus
Key switch position AUTO
Thermo-click with safe isolation
Breaking resistance
Selector switch (Positions: REV - OFF - FWD)
Key switch position OFF/RESET
Manual override switch
Control unit
IGBT inverter
Key switch position HAND
2 Actuator outputs
Braking resistance
PTC thermistor monitoring
Internal DC link
PC connection
Brake chopper with braking resistance for dynamic braking
3 fixed speeds
1 potentiometer speed
4-quadrant operation possible
General
NEMA 12
C1: for conducted emissions only
AC voltage
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
Synchronous reluctance motors
U/f control
PM and LSPM motors
Sensorless vector control (SLV)
At 40 °C
400 V AC, 3-phase
AC voltage
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length