An Eaton Moeller RASP5-4420EIP-412R100S1 operates as a frequency inverter designed to manage motor speeds and enhance overall mechanical efficiency in complex production environments. These electronic drives are commonly installed to control conveyor systems, pumps, and fans where variable operational speeds are required. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 4.3 A
- Power consumption: 46 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 0
- Number of analogue inputs: 0
- Number of digital outputs: 2
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
CE
RoHS
UL 61800-5-1
UL approval
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: Keypad
Key switch position AUTO
PTC thermistor monitoring
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
Control unit
IGBT inverter
2 Actuator outputs
Breaking resistance
Key switch position OFF/RESET
Braking resistance
Internal DC link
Key switch position HAND
Manual override switch
Selector switch (Positions: REV - OFF - FWD)
4-quadrant operation possible
Brake chopper with braking resistance for dynamic braking
3 fixed speeds
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, Off-delay
U/f control
Synchronous reluctance motors
PM and LSPM motors
Sensorless vector control (SLV)
For 60 s every 600 s
400 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Specification: S-7.4 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length