View larger
RASP5-4402A31-412R110S1 198794 Y7-198794 EATON ELECTRIC RASP5-4402A31-412R110S1
RASP5-4402A31-412R110S1
198794
Y7-198794
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-4402A31-412R110S1 is a specialized motor control unit utilized for managing three-phase electrical loads and automation routines. This device type integrates seamlessly into factory networks to regulate speed profiles and safeguard machinery against overloads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
UL approval
RoHS
IEC/EN 61800-5-1
Features & Functions
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Diagnostics and reset on device and via AS-Interface
Key switch position OFF/RESET
IGBT inverter
PTC thermistor monitoring
Thermo-click with safe isolation
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Breaking resistance
Manual override switch
Key switch position HAND
Braking resistance
Internal DC link
PC connection
Selector switch (Positions: REV - OFF - FWD)
Brake chopper with braking resistance for dynamic braking
3 fixed speeds
For actuation of motors with mechanical brake
STO (Safe Torque Off)
1 potentiometer speed
General
IP65
ASI
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
U/f control
Sensorless vector control (SLV)
Synchronous reluctance motors
BLDC motors
For 60 s every 600 s
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length