View larger
RASP5-4401A31-412R000S1 198781 Y7-198781 EATON ELECTRIC Frequency converter 4.3 A 400 V 50 Hz 1.5 kW Voltage..
RASP5-4401A31-412R000S1
198781
Y7-198781
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for decentralized drive solutions, this Eaton Moeller RASP5-4401A31-412R000S1 frequency converter regulates electric motor operations directly on machine frames. Frequency converters optimize dynamic response and energy consumption across conveyor systems, pumps, and fans. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 46 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
RoHS
UL 61800-5-1
UL approval
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Diagnostics and reset on device and via AS-Interface
PTC thermistor monitoring
Thermo-click with safe isolation
Key switch position OFF/RESET
Key switch position HAND
Control unit
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Key switch position AUTO
PC connection
IGBT inverter
Manual override switch
Selector switch (Positions: REV - OFF - FWD)
1 potentiometer speed
3 fixed speeds
General
NEMA 12
AS-Interface profile cable: S-7.4 for 31 modules
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
AC voltage
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.4 - 4.3 A, motor, main circuit
< 10 ms, Off-delay
BLDC motors
Sensorless vector control (SLV)
Synchronous reluctance motors
U/f control
At 40 °C
480 V AC, 3-phase
AC voltage
Center-point earthed star network (TN-S network)
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length