View larger
RASP5-2424EIP-412R000S1 198871 Y7-198871 EATON ELECTRIC RASP5-2424EIP-412R000S1
RASP5-2424EIP-412R000S1
198871
Y7-198871
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-2424EIP-412R000S1 is a frequency converter utilized in automated machinery to control three-phase motor speeds with high precision. By matching electrical output to operational load requirements, such devices help facilities reduce energy consumption and improve process control.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.4 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
CE
UL approval
RoHS
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Control unit
Key switch position OFF/RESET
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
PTC thermistor monitoring
IGBT inverter
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
2 Actuator outputs
PC connection
Manual override switch
Key switch position AUTO
Thermo-click with safe isolation
3 fixed speeds
For actuation of motors with mechanical brake
General
IP65
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
AC voltage
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
U/f control
BLDC motors
Synchronous reluctance motors
Sensorless vector control (SLV)
For 60 s every 600 s
400 V AC, 3-phase
AC voltage
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Number of slave addresses: 31 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length