View larger
RASP5-2422PNT-412R000S1 198950 Y7-198950 EATON ELECTRIC RASP5-2422PNT-412R000S1
RASP5-2422PNT-412R000S1
198950
Y7-198950
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A specialized Eaton Moeller drive component, designated as part number RASP5-2422PNT-412R000S1, is commonly integrated into automated installations to manage motor speed, torque, and directional rotation. These industrial inverter systems ensure smooth motor acceleration and protection in dynamic processing environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.4 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
UL approval
CE
IEC/EN 61800-5-1
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Thermo-click with safe isolation
Key switch position AUTO
Key switch position OFF/RESET
Control unit
Internal DC link
PTC thermistor monitoring
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Manual override switch
Key switch position HAND
PC connection
IGBT inverter
2 Actuator outputs
3 fixed speeds
1 potentiometer speed
General
NEMA 12
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
BLDC motors
Synchronous reluctance motors
Sensorless vector control (SLV)
PM and LSPM motors
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
230/277 V AC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length