View larger
RASP5-2421EIP-412R010S1 198877 Y7-198877 EATON ELECTRIC RASP5-2421EIP-412R010S1
RASP5-2421EIP-412R010S1
198877
Y7-198877
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Integrating network connectivity with motor control, the Eaton Moeller RASP5-2421EIP-412R010S1 acts as a decentralized frequency inverter for automated production systems. Decentralized drives simplify machine wiring by mounting directly onto equipment frames near the motors they govern. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.4 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
CE
UL 61800-5-1
UL approval
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: Keypad
Internal DC link
IGBT inverter
Key switch position AUTO
Key switch position OFF/RESET
2 Actuator outputs
Manual override switch
Key switch position HAND
PTC thermistor monitoring
Control unit
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
Thermo-click with safe isolation
STO (Safe Torque Off)
3 fixed speeds
1 potentiometer speed
General
IP65
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
AC voltage
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
PM and LSPM motors
Sensorless vector control (SLV)
Synchronous reluctance motors
BLDC motors
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
AC voltage
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length