View larger
RASP5-2421EIP-412R000S1 198869 Y7-198869 EATON ELECTRIC RASP5-2421EIP-412R000S1
RASP5-2421EIP-412R000S1
198869
Y7-198869
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
RASP5-2421EIP-412R000S1 198869 Y7-198869 EATON ELECTRIC RASP5-2421EIP-412R000S1 functions as a specialized electronic drive unit deployed in industrial automation setups to manage motor operations and operational feedback. Such modular components integrate within distributed control networks to provide efficient power conversion and localized motor protection. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.4 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
CE
UL approval
RoHS
Features & Functions
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Key switch position OFF/RESET
Thermo-click with safe isolation
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
PC connection
IGBT inverter
Manual override switch
2 Actuator outputs
Internal DC link
Key switch position HAND
Control unit
Key switch position AUTO
PTC thermistor monitoring
1 potentiometer speed
3 fixed speeds
General
IP65
C1: for conducted emissions only
AC voltage
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.2 - 2.4 A, motor, main circuit
< 10 ms, Off-delay
BLDC motors
Synchronous reluctance motors
PM and LSPM motors
U/f control
For 60 s every 600 s
400 V AC, 3-phase
AC voltage
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length