View larger
RASP5-2420PNT-4120010S1 198940 Y7-198940 EATON ELECTRIC RASP5-2420PNT-4120010S1
RASP5-2420PNT-4120010S1
198940
Y7-198940
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller RASP5-2420PNT-4120010S1 acts as a centralized variable frequency drive designed to govern electrical motor operations across complex automated machinery. These devices deliver smooth acceleration profiles and protect equipment from grid fluctuations in modern factories.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.4 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
RoHS
IEC/EN 61800-5-1
UL 61800-5-1
Features & Functions
Parameterization: Fieldbus
Parameterization: drivesConnect
Parameterization: Keypad
Thermo-click with safe isolation
PC connection
Key switch position OFF/RESET
Internal DC link
IGBT inverter
2 Actuator outputs
Control unit
Key switch position AUTO
Selector switch (Positions: REV - OFF - FWD)
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
PTC thermistor monitoring
1 potentiometer speed
STO (Safe Torque Off)
General
IP65
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
0.2 - 2.4 A, motor, main circuit
< 10 ms, Off-delay
Sensorless vector control (SLV)
U/f control
BLDC motors
PM and LSPM motors
For 60 s every 600 s
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Cable
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length