View larger
RASP-510AI1SL-C320S1 150175 EATON ELECTRIC Speed controller, 400 V AC, 3-phase, 5.6 A, fan, braking resistan..
RASP-510AI1SL-C320S1
150175
EATON - MOELLER
1 Pcs.
Automation > Speed controller
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built with integrated cooling fans and braking resistance, the Eaton Moeller RASP-510AI1SL-C320S1 speed controller handles demanding motor operation profiles. Frequency converters are essential in modern factories for controlling torque, managing speed variations, and protecting motors from electrical anomalies.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- optional: Faster stop if external 24 V fails, without manual override switch
- Fan: with fan
- Braking resistance: with braking resistance
- Rated operational voltage: Ue= 400 V AC, 3-phase, 480 V AC, 3-phase
- Output voltage with Ve: U2= 400 V AC, 3-phase
- Mains voltage (50/60Hz): ULN= 380 (-15%) - 480 (+10%) V
- At 150% overload: Ie= 5.6 A
- AS-Interface profile cable: S-7.4 for 31 modules
- Standards: IEC/EN 61800-5-1, UL 61800-5-1, Guideline 2011/65/EU (RoHS), CE approval, UL approval
More info
▲Delivery program
480 V AC, 3-phase
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
optional: 4 sensor inputs with M12-Y adapter for switchover to creep speed
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
3 fixed speeds and 1 potentiometer speed
can be switched over from U/f to (vector) speed control
with selector switch REV - OFF - FWD
optional: Faster stop if external 24 V fails
Technical data
UL 61800-5-1
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
IEC/EN 50178 %
IEC/EN 60068-2-27 g
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
NEMA12
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
at 40 °C
adjustable 1.5 - 16 kHz
adjustable A
with fan
with braking resistance
Specification: S-7.4
Number of slave addresses: 31