Featuring a manual override switch and integrated braking resistance, the Eaton Moeller RASP-312AI1S0-C32RS1 speed controller delivers precise velocity regulation for three-phase drives. Industrial automation systems use these controllers to optimize motor performance and ensure reliable stopping.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- optional: Faster stop if external 24 V fails, with manual override switch
- Fan: without fan
- Braking resistance: with braking resistance
- Rated operational voltage: Ue= 400 V AC, 3-phase, 480 V AC, 3-phase
- Output voltage with Ve: U2= 400 V AC, 3-phase
- Mains voltage (50/60Hz): ULN= 380 (-15%) - 480 (+10%) V
- At 150% overload: Ie= 3.3 A
- AS-Interface profile cable: S-7.4 for 31 modules
- Standards: IEC/EN 61800-5-1, UL 61800-5-1, Guideline 2011/65/EU (RoHS), CE approval, UL approval
More info
▲Delivery program
480 V AC, 3-phase
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
optional: 4 sensor inputs with M12-Y adapter for switchover to creep speed
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
3 fixed speeds and 1 potentiometer speed
can be switched over from U/f to (vector) speed control
with selector switch REV - OFF - FWD
optional: Faster stop if external 24 V fails
integrated brake chopper with braking resistance for dynamic braking
Technical data
UL 61800-5-1
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
IEC/EN 50178 %
IEC/EN 60068-2-27 g
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
NEMA12
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
at 40 °C
adjustable 1.5 - 16 kHz
adjustable A
optional RASP-FAN-S1 on heat sink, temperature-controlled
without fan
with braking resistance
(max. 6 A for 120 ms) A
Specification: S-7.4
Number of slave addresses: 31