View larger
RASP-302AI1S0-C32RS1 150209 EATON ELECTRIC Speed controller, 400 V AC, 3-phase, 3.3 A, manual override switc..
RASP-302AI1S0-C32RS1
150209
EATON - MOELLER
1 Pcs.
Automation > Speed controller
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a speed controller with a manual override switch, the Eaton Moeller RASP-302AI1S0-C32RS1 provides dependable frequency conversion for industrial motor control tasks. Speed controllers help maintain consistent operation speeds across complex conveyor and processing systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- optional: Faster stop if external 24 V fails, with manual override switch
- Fan: without fan
- Braking resistance: without braking resistance
- Rated operational voltage: Ue= 400 V AC, 3-phase, 480 V AC, 3-phase
- Output voltage with Ve: U2= 400 V AC, 3-phase
- Mains voltage (50/60Hz): ULN= 380 (-15%) - 480 (+10%) V
- At 150% overload: Ie= 3.3 A
- AS-Interface profile cable: S-7.4 for 31 modules
- Standards: IEC/EN 61800-5-1, UL 61800-5-1, Guideline 2011/65/EU (RoHS), CE approval, UL approval
More info
▲Delivery program
480 V AC, 3-phase
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
optional: 4 sensor inputs with M12-Y adapter for switchover to creep speed
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
3 fixed speeds and 1 potentiometer speed
can be switched over from U/f to (vector) speed control
with selector switch REV - OFF - FWD
optional: Faster stop if external 24 V fails
Technical data
UL 61800-5-1
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
IEC/EN 50178 %
IEC/EN 60068-2-27 g
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
NEMA12
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
at 40 °C
adjustable 1.5 - 16 kHz
adjustable A
optional RASP-FAN-S1 on heat sink, temperature-controlled
without fan
without braking resistance
(max. 6 A for 120 ms) A
Specification: S-7.4
Number of slave addresses: 31