Eaton Moeller RASP-204AI1S0-C32RS1 is deployed as a Rapid Link speed controller to manage electrical motor speeds and operational trajectories in manufacturing plants. These devices offer robust external control capabilities for distributed machine layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mounting method (EF000003): Surface mounted
- Colour (EF000007): Grey
- RAL-number (EF000116): 0
- Nominal current (EF000001): 2.4 A
- Output voltage (EF003933): 0 V
- Number of phases (EF000351): 3
- Power control stepless (EF000661): Yes
- Number of steps (EF002426): 0
- Basic element without cover (EF008182): Yes
- Method of operation (EF000006): Key
- Switching contact (EF001141): No
- With temperature sensor (EF006034): Yes
- Height (EF000040): 182 mm
- Width (EF000008): 220 mm
- Depth (EF000049): 285 mm
- Degree of protection (IP) (EF005474): IP65
More info
▲Delivery program
480 V AC, 3-phase
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
optional: 4 sensor inputs with M12-Y adapter for switchover to creep speed
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
3 fixed speeds and 1 potentiometer speed
can be switched over from U/f to (vector) speed control
with selector switch REV - OFF - FWD
optional: Faster stop if external 24 V fails
Technical data
UL 61800-5-1
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
IEC/EN 50178 %
IEC/EN 60068-2-27 g
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
NEMA12
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
at 40 °C
adjustable 1.5 - 16 kHz
adjustable A
optional RASP-FAN-S1 on heat sink, temperature-controlled
without fan
without braking resistance
(max. 6 A for 120 ms) A
Specification: S-7.4