Eaton Moeller RAMO5-W424EIP-412RS1 devices offer advanced reversing motor starter functionality with integrated network connectivity for automated applications. These distributed controllers streamline machine integration in modern production environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter: Reversing starter
- With short-circuit release: Yes
- Rated control supply voltage AC 50 Hz: 0 V
- Rated control supply voltage AC 60 Hz: 0 V
- Rated control supply voltage DC: 0 V
- Voltage type for actuating: DC
- Rated operation power at AC-3, 230 V, 3-phase: 0 kW
- Rated operation power at AC-3, 400 V: 3 kW
- Rated power, 460 V, 60 Hz, 3-phase: 2.238 kW
- Rated power, 575 V, 60 Hz, 3-phase: 0 kW
- Rated operation current Ie: 6.6 A
- Rated operation current at AC-3, 400 V: 6.6 A
- Overload release current setting: 0.3 A
- Power consumption: 8 W
- Ambient temperature, upper operating limit: 55 °C
- Temperature compensated overload protection: Yes
More info
▲General specifications
IEC/EN 60947-4-2
UL approval
RoHS
CCC
UL 60947-4-2
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Parameterization: drivesConnect
Key switch position HAND
2 Actuator outputs
Key switch position AUTO
Manual override switch
Electronic motor protection
Thermo-click
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Key switch position OFF/RESET
Short-circuit release
External reset possible
Temperature compensated overload protection
General
IP65
AC voltage
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
Max. 1000 m
< 95 %, no condensation
Main circuit
0.3 - 6.6 A, motor, main circuit
480 V AC, 3-phase
AC voltage
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)