View larger
RAMO5-W420PNT-412RS1 199137 Y7-199137 EATON ELECTRIC RAMO5-W420PNT-412RS1
RAMO5-W420PNT-412RS1
199137
Y7-199137
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
RAMO5-W420PNT-412RS1 manufactured by Eaton Moeller, part number RAMO5-W420PNT-412RS1, functions as an advanced reversing starter engineered to control motor direction and protect industrial electrical loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Reversing starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0 kW
- Rated operation power at AC-3, 400 V (EF001364): 3 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 2.238 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 6.6 A
- Rated operation current at AC-3, 400 V (EF009602): 6.6 A
- Overload release current setting (EF002336): 0.3 A
- Power consumption (EF000346): 8 W
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
More info
▲General specifications
CE
RoHS
IEC/EN 60947-4-2
CCC
UL approval
Features & Functions
Parameterization: drivesConnect
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Key switch position OFF/RESET
2 Actuator outputs
Electronic motor protection
Thermo-click
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Manual override switch
Thermistor monitoring PTC
Short-circuit release
Temperature compensated overload protection
General
NEMA 12
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
0.3 - 6.6 A, motor, main circuit
400 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.