View larger
RAMO5-W211A31-4120S1 199085 Y7-199085 EATON ELECTRIC RAMO5-W211A31-4120S1
RAMO5-W211A31-4120S1
199085
Y7-199085
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller reversing starter (RAMO5-W211A31-4120S1) is engineered to control and reverse the direction of rotation of three-phase electric motors in industrial environments. Motor starters provide reliable switching, operational safety, and integrated thermal or current-based overload protection to safeguard machinery from excessive electrical loads.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter: Reversing starter
- With short-circuit release: Yes
- Rated control supply voltage AC 50 Hz: 0 V
- Rated control supply voltage AC 60 Hz: 0 V
- Rated control supply voltage DC: 0 V
- Voltage type for actuating: DC
- Rated operation power at AC-3, 230 V, 3-phase: 0 kW
- Rated operation power at AC-3, 400 V: 3 kW
- Rated power, 460 V, 60 Hz, 3-phase: 2.238 kW
- Rated power, 575 V, 60 Hz, 3-phase: 0 kW
- Rated operation current Ie: 6.6 A
- Rated operation current at AC-3, 400 V: 6.6 A
- Overload release current setting: 0.3 A
- Power consumption: 8 W
- Ambient temperature, upper operating limit: 55 °C
- Temperature compensated overload protection: Yes
More info
▲General specifications
RoHS
UL 60947-4-2
UL approval
CCC
IEC/EN 60947-4-2
Features & Functions
Parameterization: drivesConnect
Diagnostics and reset on device and via AS-Interface
Parameterization: Fieldbus
Parameterization: Keypad
Thermo-click
Key switch position HAND
Electronic motor protection
Thermistor monitoring PTC
Key switch position AUTO
Key switch position OFF/RESET
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Short-circuit release
External reset possible
Temperature compensated overload protection
General
IP65
ASI
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Max. 2000 m
Max. 1000 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)