View larger
RAMO5-W204A32-412RS1 199112 Y7-199112 EATON ELECTRIC RAMO5-W204A32-412RS1
RAMO5-W204A32-412RS1
199112
Y7-199112
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RAMO5-W204A32-412RS1 is a reversing starter designed to control and protect industrial electric motors within automated setups. Motor starters safely manage operational currents and facilitate reliable switching during repetitive cycling tasks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Reversing starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0 kW
- Rated operation power at AC-3, 400 V (EF001364): 3 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 2.238 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 6.6 A
- Rated operation current at AC-3, 400 V (EF009602): 6.6 A
- Overload release current setting (EF002336): 0.3 A
- Power consumption (EF000346): 8 W
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
More info
▲General specifications
UL approval
UL 60947-4-2
CCC
CE
IEC/EN 60947-4-2
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Diagnostics and reset on device and via AS-Interface
Parameterization: Fieldbus
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermistor monitoring PTC
Thermo-click
Manual override switch
Key switch position OFF/RESET
Electronic motor protection
Key switch position HAND
Short-circuit release
External reset possible
Temperature compensated overload protection
General
IP65
ASI
Phase-earthed AC supply systems are not permitted.
AC voltage
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
Max. 1000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
AC voltage
Motor rating
Braking function
Short-circuit rating
Control circuit
400/480 V AC (external brake 50/60 Hz)
Communication
Number of slave addresses: 62 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA