View larger
RAMO5-W200A31-412RS1 199099 Y7-199099 EATON ELECTRIC RAMO5-W200A31-412RS1
RAMO5-W200A31-412RS1
199099
Y7-199099
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Electric RAMO5-W200A31-412RS1 is an Eaton Electric RAMO5-W200A31-412RS1 designed to manage reversing motor operations in decentralized automation environments. Decentralized starters reduce cabinet space requirements by mounting directly onto machines or support structures near the driven load while offering robust electronic protection. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Reversing starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0 kW
- Rated operation power at AC-3, 400 V (EF001364): 3 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 2.238 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 6.6 A
- Rated operation current at AC-3, 400 V (EF009602): 6.6 A
- Overload release current setting (EF002336): 0.3 A
- Power consumption (EF000346): 8 W
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
More info
▲General specifications
CCC
UL approval
CE
RoHS
UL 60947-4-2
Features & Functions
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Key switch position OFF/RESET
Electronic motor protection
Key switch position HAND
Manual override switch
Key switch position AUTO
Thermistor monitoring PTC
Short-circuit release
Temperature compensated overload protection
General
NEMA 12
ASI
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
Max. 1000 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Short-circuit rating
Control circuit
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA