View larger
RAMO-D04AI2S-C32RS1 171784 EATON ELECTRIC DOL starter, manual override switch, 400 V AC, 3-phase, 6.6 A, Con..
RAMO-D04AI2S-C32RS1
171784
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller repair switch and DOL starter, part number RAMO-D04AI2S-C32RS1, provides local manual isolation and motor control capabilities for automated systems. Maintenance and repair switches are critical safety components used to disconnect electrical power directly at machinery during servicing operations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter: Repair switch
- With short-circuit release: Yes
- Rated control supply voltage AC 50 Hz: 0 V
- Rated control supply voltage AC 60 Hz: 0 V
- Rated control supply voltage DC: 0 V
- Voltage type for actuating: AC
- Rated operation power at AC-3, 230 V, 3-phase: 0 kW
- Rated operation power at AC-3, 400 V: 3 kW
- Rated power, 460 V, 60 Hz, 3-phase: 2.238 kW
- Rated power, 575 V, 60 Hz, 3-phase: 0 kW
- Rated operation current Ie: 6.6 A
- Rated operation current at AC-3, 400 V: 6.6 A
- Overload release current setting: 0.3 A
- Ambient temperature, upper operating limit: 55 °C
- Temperature compensated overload protection: Yes
- Release class: CLASS 10
More info
▲Delivery program
480 V AC, 3-phase
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Connections pluggable in power section
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
With electronic motor protection for allocated motor power from 0.09 – 3.0 kW (400 V)/0.125 – 3.0 HP (480 V)
Technical data
UL 60947-4-2
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
CCC approval
IEC/EN 50178 %
IEC/EN 60068-2-27 g
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
NEMA12
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
adjustable A
(max. 6 A for 120 ms) A
Specification: S-7.A.E.
Number of slave addresses: 62