EATON - MOELLER PXS24S-e8/F/ORT-IT PXS24S-e8/F/ORT-IT PXS24S08A001 EATON ELECTRIC Electronic overcurrent protection for 24V DC, fix 8A with tri.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PXS24S-e8/F/ORT-IT PXS24S08A001 EATON ELECTRIC Electronic overcurrent protection for 24V DC, fix 8A with tri..

PXS24S-e8/F/ORT-IT

PXS24S08A001

PXS24S08A001

EATON - MOELLER

1 Pcs.

Electronic overcurrent protection for 24V DC, fix 8A with tripped signal out-, control in-put and supply terminals Protec. Electronic overcurrent for 24V DC, fixed 8A with signal Reliable, modular, elektronic overcurrent protection for 24V DC systems, simple busbar solution, fix or variable amperage, optionally with control input and error message output,  plug-in terminals (+ 24V and 0V) for up to 3 loads, robust design, local and (optional) remote-controllable

Automation > Current monitoring relay
Electronic overcurrent protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Electronic overcurrent protection for 24V DC, fix 8A with tripped signal out-, control in-put and supply terminals
Reliable, modular, elektronic overcurrent protection for 24V DC systems, simple busbar solution, fix or variable amperage, optionally with control input and error message output,  plug-in terminals (+ 24V and 0V) for up to 3 loads, robust design, local and (optional) remote-controllable

Delivery program

Basic function
Automation engineering 24V
Number of channels
1
Protection
Electronic
Rated current [In]
8 A
Rated operating voltage [Un]
24 V
Standard/Approval
CE
UL508

Technical data

Electrical
Operational voltage [UB]
24V DC (15 .. 30V DC)
Rated operational current fix [IN]
8 A
Overload current and short-circuit current trip
Type 1.3 x INwith active current limitation
Trip time for electronic trip
110 ms
Capacitive loads
Up to 20,000 µF
Inductive loads
Up to 13 A
Mechanical
Width
17.5 mm
Depth
119.2 mm
TerminalsInput terminals
3x LINE (+) and 3x GND (-)
TerminalsOutput Terminals
3x LOAD (+) and 3x GND (-)
TerminalsTerminal type:
Push in terminals
TerminalsTerminal capacity
2.5 (flexible with ferrules)
4 (rigid) mm²
Communication connectorCommunication connector
Two remote signaling outputs (internally connected to each other)
Two remote signaling inputs (internally connected to each other)
1x GND
Communication connectorTerminal type:
Push in terminals
Communication connectorTerminal capacity
0.75 (flexible with ferrule)
1.5 (rigid) mm²
Communication connectorRemote signaling output
Triggered
Via communication connector (conforming to IEC 61131-2), class: 0.1 A
Type1/Type2 and Type3
Digital inputs
A max. of 30 PXS24V can be connected simultaneously
External signal sources up to 0.2 A@24 V (EATON RMQ series, etc.)
Communication connectorRemote control input
On/Off/Reset
Via communication connector (conforming to IEC 61131-2), type 1/type 3
A max. of 30 PXS24V can be connected simultaneously
Communication connectorSequential control
Via communication connector
Busbars
LINE (+) and GND (-); max 60A in various lengths of up to 1m
Mounting
snap-fit on mounting rail TH35 (EN 60715)
Status LED
Two-colored
Green = OK; Red = Triggered
OFF = Channel not in operation
Slide switch
On/Off/Reset
Text field
17,5 x 6 mm
Degree of Protection
IP20
Ambient temperature
-30 - +55 °C
Permissible storage and transport temperatures
-40 - +100 °C
Base dimension
92.5 mm

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
8 A
Equipment heat dissipation, current-dependent [Pvid]
1.1 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Relays (EG000019) / Current monitoring relay (EC001440)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Current monitoring equipment ([email protected] [AKF096014])
Type of electric connection
Plug-in connection
With detachable clamps
No
Single-phase under current possible
No
Three-phase under current possible
No
Single-phase over current possible
No
Three-phase over current possible
No
Single-phase hysteresis possible
No
Three-phase hysteresis possible
No
Contains function DC-voltage under current
No
Contains function DC-voltage over current
Yes
Function DC-current hysteresis
No
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
16 - 30 V
Voltage type for actuating
DC
Current measurement range
0 - 10.4 A
Min. adjustable delay-on energization time
0 s
Max. permitted delay-on energization time
0 s
Min. adjustable off-delay time
0 s
Max. permitted off-delay time
0 s
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
External current transformer
No
Width
18 mm
Height
93 mm
Depth
127 mm

ETIM for PXS24S08A001 Relays (EC001440)
Feature Name Feature Value
Type of electric connection (EF003961) Plug-in connection
With detachable clamps (EF003340) No
External power supply required (EF003292) No
Current measuring range (EF000417) 0 A
Single-phase under current possible (EF003405) No
Three-phase under current possible (EF003406) No
Single-phase overcurrent possible (EF003407) No
Three-phase overcurrent possible (EF003408) No
Single-phase hysteresis possible (EF003394) No
Three-phase hysteresis possible (EF003395) No
Contains function DC-voltage under current (EF003409) No
Contains function DC-voltage overcurrent (EF003410) Yes
Function DC-current hysteresis (EF003411) No
Min. adjustable delay-on energization time (EF008190) 0 s
Max. permitted delay-on energization time (EF008189) 0 s
Min. adjustable off-delay time (EF008192) 0 s
Max. permitted off-delay time (EF008191) 0 s
External current transformer (EF001923) No
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 1
Number of contacts as change-over contact (EF008257) 0
Width (EF000008) 18 mm
Height (EF000040) 93 mm
Depth (EF000049) 127 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.