View larger
E57RAL18T111ED
136076
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Basic function | Inductive Sensors | ||
Product range | E57 Premium+ Series | ||
Connection | 3-wire | ||
Design (outer dimensions) | mm | M18 x 1 | |
Rated operational voltage | Ue | 6 - 48 V DC | |
Rated switching distance | Sn | mm | 8 |
Type of mounting | Non-flush | ||
Switching type | PNP | ||
For connection of: | Plug-in connection M12 x 1 | ||
Contacts | |||
N/O = Normally open | 1 N/O | ||
Material | Stainless steel | ||
Degree of Protection | IP67 |
| General | |||
Standards | IEC/EN 60947-5-2 | ||
Ambient temperature | -25 - +70 | ||
Mechanical shock resistance | g | 30 Shock duration 11 ms | |
Degree of Protection | IP67 | ||
| Characteristics | |||
Rated switching distance | |||
Rated switching distance | Sn | mm | 8 |
Repetition accuracy of Sn | % | 3 | |
Temperature drift of Sn | % | 10 | |
Switching hysteresis of Sn | % | 15 | |
Rated operational voltage | Ue | 6 - 48 V DC | |
Operating current in the switched state at 24 V DC | Ib | mA | 10 |
Maximum load current | Ie | mA | < 500 (6 - 30 V DC) |
Voltage drop at Ie | Ud | V | 2.5 |
Switching Frequency | Hz | 500 | |
Min. load current | Ie | mA | 1 |
Residual current through the load in the blocked state at 230 V AC and 24 V DC | Ir | mA | 0.1 |
Switching state display | LED | Red | |
Connection | 3-wire | ||
Contacts | |||
N/O = Normally open | 1 N/O | ||
Style | |||
Design (outer dimensions) | mm | M18 x 1 | |
For connection of: | Plug-in connection M12 x 1 | ||
Material | Stainless steel | ||
| Product Standards | UL 508; IEC60947-5-2; CE marking | ||
| UL File No. | E166051 | ||
| UL Category Control No. | NRKH, NRKH7 | ||
| North America Certification | UL listed | ||
| Max. Voltage Rating | 48 V DC | ||
| Degree of Protection | IEC: IP67, IP69K; UL/CSA Type: 4, 4x, 6, 6P, 12, 13 |
| Sensors (EG000026) / Inductive proximity switch (EC002714) | |||
| Electric engineering, automation, process control engineering / Binary sensor technology, safety-related sensor technology / Proximity switch / Inductive proximity switch ([email protected] [AGZ376015]) | |||
Width sensor | mm | 0 | |
Height of sensor | mm | 0 | |
Length of sensor | mm | 93 | |
Diameter sensor | mm | 18 | |
Mechanical mounting condition for sensor | Not flat | ||
Switching distance | mm | 8 | |
Suitable for safety functions | No | ||
Type of switch function | Normally open contact | ||
Type of switching output | PNP | ||
Type of electric connection | Connector M12 | ||
Type of electric connection | Plug-in connection M12 | ||
Number of semiconductor outputs with signalling function | 1 | ||
Number of contact energized outputs with signalling function | 0 | ||
Number of protected semiconductor outputs | 0 | ||
Number of protected contact energized outputs | 0 | ||
Type of actuation | Metallic Target | ||
Type of interface | None | ||
Type of interface for safety communication | None | ||
Construction type housing | Cylinder, screw-thread | ||
Coating housing | Other | ||
Cascadable | No | ||
Category according to EN 954-1 | B | ||
SIL according to IEC 61508 | None | ||
Performance level acc. EN ISO 13849-1 | None | ||
Max. output current at protected output | mA | 0 | |
Supply voltage | V | 6 - 48 | |
Rated control supply voltage Us at AC 50HZ | V | 0 - 0 | |
Rated control supply voltage Us at AC 60HZ | V | 0 - 0 | |
Rated control supply voltage Us at DC | V | 6 - 48 | |
Voltage type | DC | ||
Voltage type | DC | ||
Switching frequency | Hz | 500 | |
With monitoring function downstream switching devices | No | ||
Material housing | Metal | ||
Compression-resistant | No | ||
Explosion safety category for gas | None | ||
Explosion safety category for dust | None | ||
Interference resistance to magnetic fields | - | ||
| Feature Name | Feature Value |
|---|---|
| Width sensor (EF007094) | 0 mm |
| Height of sensor (EF007283) | 0 mm |
| Length of sensor (EF007334) | 93 mm |
| Diameter sensor (EF007111) | 18 mm |
| Mechanical mounting condition for sensor (EF004041) | Not flat |
| Switching distance (EF003647) | 8 mm |
| Suitable for safety functions (EF001597) | No |
| Type of switch function (EF003963) | Normally open contact |
| Type of switching output (EF003962) | PNP |
| Type of electric connection (EF003961) | Plug-in connection |
| Number of semiconductor outputs with signalling function (EF003945) | 1 |
| Number of contact energized outputs with signalling function (EF003946) | 0 |
| Number of protected semiconductor outputs (EF003951) | 0 |
| Number of protected contact energized outputs (EF003952) | 0 |
| Type of actuation (EF006949) | Metallic Target |
| Type of interface (EF006977) | None |
| Type of interface for safety communication (EF003956) | None |
| Construction type housing (EF004008) | Cylinder, screw-thread |
| Cascadable (EF000507) | No |
| SIL according to IEC 61508 (EF009889) | None |
| Performance level according to EN ISO 13849-1 (EF007399) | None |
| Max. output current at protected output (EF004035) | 0 mA |
| Supply voltage (EF004127) | 6 V |
| Rated control supply voltage AC 50 Hz (EF003978) | 0 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 0 V |
| Rated control supply voltage DC (EF003980) | 6 V |
| Voltage type (EF000187) | DC |
| Switching frequency (EF003587) | 500 Hz |
| With monitoring function downstream switching devices (EF004052) | No |
| Housing material (EF001596) | Metal |
| Compression-resistant (EF007106) | No |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Degree of protection (NEMA) (EF011959) | 4X |