View larger
SN3-000-MMEU8 100646 EATON ELECTRIC Moni stabilized power source
SN3-000-MMEU8
100646
EATON - MOELLER
1 Pcs.
Automation > PLC system power supply
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller stabilized power source (part number SN3-000-MMEU8) delivers regulated DC output to sensitive control electronics and industrial automation machinery.
Regulated power supplies protect downstream components from voltage fluctuations and electrical noise commonly found in heavy industrial environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Insulation voltage Rated insulation voltage: U i
- Power consumption: P max.
- Rated operational current for specified heat dissipation: I n
- Heat dissipation per pole, current-dependent: P vid
- Equipment heat dissipation, current-dependent: P vid
- Static heat dissipation, non-current-dependent: P vs
- Heat dissipation capacity: P diss
- IL05012005Z (IL05012005Z) Power supply unit: >>
- Redundancy (EF003156): No
- Suitable for safety functions (EF001597): No
- Width (EF000008): 57 mm
- Height (EF000040): 54 mm
- Depth (EF000049): 24 mm
More info
▲Product range | Signal module for SN3-...-EU8 power supply unit | ||
Description | LED display: Input o.k. LED display: Output o.k. LED display: Remote off Relay output 1 changeover: Input o.k. Relay output 1 changeover: Output o.k. Remote ON-/OFF function for external switching | ||
Nominal input voltage | 110 - 240 V AC 100 - 350 DC | ||
Input voltage range | 70 - 264 V AC 80 - 350 V DC | ||
For use with | SN3-50-EU8 SN3-100-EU8 SN3-200-EU8 |
| General | |||
Standards | IEC 61204 73/23/EWG 89/336/EWG EN 50178, EN 60950, UL 60950, UL 508 | ||
Duty factor | % | 100 | |
Dimensions (W x H x D) | mm | 56,25 x 54 x 24 (in installed state) | |
Weight | kg | 0.065 | |
Terminal capacities | mm2 | ||
Flexible with ferrule | mm2 | 0.2…2.5 (22…14 AWG) | |
Flexible without ferrule | mm2 | 0.2…2.5 (22…14 AWG) | |
Massive | mm2 | 0.2…4 (22…14 AWG) | |
Degree of protection | |||
Enclosures | IP20 | ||
Terminals | IP20 | ||
Protection class | 2 | ||
Mounting | Plugged into power supply unit | ||
Fixing | Snap fastener, tool-less | ||
Vibrations (IEC/EN 60068-2-6) | 1…57 Hz, amplitude ±0.075 mm, 57…100 Hz, 5 g | ||
Mechanical shock resistance (IEC 60068-2-27) | 5 g all directions | ||
| Environmental compatibility | |||
Ambient temperature | |||
Operation | °C | -25 - +70 | |
Storage | °C | - 40 - + 85 | |
Climatic proofing | 93% at +40°C according to IEC 60068-2-3, no condensation | ||
Climatic class (IEC) | 3K3 according to EN 60721 | ||
| Insulation voltage | |||
Rated insulation voltage | Ui | V AC | 250 nach IEC 60974-1, EN 50178, VDE 0160 |
Power supply/measuring circuit/relay outputs | Safe isolation according to EN 50178, EN 60950 | ||
Rated impulse withstand voltage between all insulated circuits | Uimp | kV | 4 according to IEC 664, VDE 0110 |
Test voltage between all circuits | kV | 2.5 AC (routine test) | |
Overvoltage category/pollution degree | according to EN 60950, Class 2 | ||
| Input circuit | |||
Nominal input voltage | 110 - 240 V AC 100 - 350 DC | ||
Instructions | supplied from the input circuit of the power supply | ||
Input voltage range | 70 - 264 V AC 80 - 350 V DC | ||
Power consumption | VA | 2.5 | |
Power consumption | Pmax. | W | 1.5 |
Heat dissipation | W | Max. 1.5 | |
| REMOTE-OFF input | |||
| potential-free | |||
Switch off | R | ||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 1.5 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 70 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
| PLC's (EG000024) / PLC system power supply (EC000599) | |||
| Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / SPS system power supply ([email protected] [AKE532011]) | |||
Input voltage at AC 50 Hz | V | 85 - 264 | |
Input voltage at AC 60 Hz | V | 85 - 264 | |
Input voltage at DC | V | 80 - 350 | |
Type of voltage (input voltage) | AC/DC | ||
Max. input current AC 50 Hz | A | 0 | |
Max. input current AC 60 Hz | A | 0 | |
Max. input current DC | A | 0 | |
Type of output voltage | DC | ||
Output voltage at AC 50 Hz | V | 0 - 0 | |
Output voltage at AC 60 Hz | V | 0 - 0 | |
Output voltage at DC | V | 0 - 0 | |
Max. output current AC 50 Hz | A | 0 | |
Max. output current AC 60 Hz | A | 0 | |
Max. output current DC | A | 0 | |
Redundancy | Yes | ||
Suitable for safety functions | No | ||
Width | mm | 90 | |
Height | mm | 54 | |
Depth | mm | 24 | |