View larger
LS-11 266109 Y7-266109 EATON ELECTRIC Position switch, 1N/O+1N/C, rounded plunger
LS-11
266109
Y7-266109
EATON - MOELLER
10 Pcs.
Automation > End switch
Position Switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for general machine control, the Eaton Moeller LS-11 position switch features a rounded plunger actuator and slow-action switching contacts. Mechanical position switches detect the presence, passage, or end-of-travel of objects along automated production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width sensor (EF007094): 31 mm
- Diameter sensor (EF007111): 0 mm
- Height of sensor (EF007283): 61 mm
- Length of sensor (EF007334): 33.5 mm
- Rated operation current Ie at AC-15, 24 V (EF007084): 6 A
- Rated operation current Ie at AC-15, 125 V (EF007082): 6 A
- Rated operation current Ie at AC-15, 230 V (EF001385): 6 A
- Rated operation current Ie at DC-13, 24 V (EF007087): 3 A
- Rated operation current Ie at DC-13, 125 V (EF007085): 0.8 A
- Rated operation current Ie at DC-13, 230 V (EF001386): 0.3 A
- Switching function (EF000189): Slow-action switch
- Switching function latching (EF007447): No
- Output electronic (EF006987): No
- Forced opening (EF006694): Yes
- Number of safety auxiliary contacts (EF006940): 1
- Number of contacts as normally closed contact (EF008255): 1
More info
▲General specifications
IEC/EN 60947
UL 508
CSA File No.: 012528
UL Category Control No.: NKCR
CSA Class No.: 3211-03
UL File No.: E29184
CE
UL
CSA
IEC/EN 60947-5
Features & Functions
Insulated material
Positive opening
Forced opening
General
NEMA Other
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
Electrical rating
Actuator
For angle of actuation α = 0°/30°
Contacts
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)