Designed for secure power switching in demanding electrical architectures, the PN2-250-BT 110310 Y7-110310 EATON ELECTRIC Switch-disconnector 3p, 250A terminals from Eaton Moeller provides dependable circuit interruption. Panel builders utilize three-pole switch-disconnectors to interrupt load currents and provide visual isolation gaps inside commercial and industrial power distribution assemblies. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): Yes
- Version as reversing switch (EF009408): No
- Number of switches (EF005586): 1
- Max. rated operation voltage Ue AC (EF007355): 690 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 250 A
- Rated permanent current at AC-23, 400 V (EF011777): 0 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 3.5 kA
- Rated operation power at AC-23, 400 V (EF007027): 132 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 0 kA
More info
▲General specifications
IEC/EN 60947
Product specifications
Version as maintenance-/service switch
Version as main switch
Ground mounting
Intermediate mounting
Fixed
Built-in device fixed built-in technique
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
Other
250 A (690 V AC-22/23A, making and breaking capacity)
IP20
IP40 (with insulating surround)
IP10 (tunnel terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 24 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Max. 8 segments of 15.5 mm x 0.8 mm (2x) at box terminal
7500 operations at 400 V AC-3
10000 operations at 400 V AC-1
5000 operations at 690 V AC-3
10000 operations at 415 V AC-1
7500 operations at 690 V AC-1
Disconnectors/main switches
80 kA at 690 V
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V
PN2(N2)-160…250: 250 AgGgL
M8 at rear-side screw connection
Max. 24 mm x 8 mm direct at switch rear-side connection
6 mm² - 16 mm² (2x) at box terminal
10 mm² - 16 mm² (1x) at box terminal
10 mm² - 16 mm² (1x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
16 mm² (1x) at tunnel terminal
10 mm² - 16 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at 1-hole tunnel terminal