View larger
PKZM0-6,3/NHI11 039425 Y7-39425 EATON ELECTRIC Motor-protective circuit-breaker, 3p+1N/O+1N/C, Ir 4-6.3A, sc..
PKZM0-6,3/NHI11
039425
Y7-39425
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller PKZM0-6,3/NHI11 motor-protective circuit-breaker provides complete thermal-magnetic motor protection alongside built-in auxiliary contact signaling. Industrial control specialists integrate these units into starter assemblies to protect motors against overloads while feeding operational status data to PLCs. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: PKZM0-6,3/NHI11
- Catalogue code: 039425
- Catalogue title: PKZM0-6,3/NHI11 039425 Y7-39425 EATON ELECTRIC Motor-protective circuit-breaker, 3p+1N/O+1N/C, Ir 4-6.3A, sc..
- Product description: General specifications Product Name Eaton Moeller series PKZM0 Motor-protective circuit-breaker Catalog Number 039425 Model Code PKZM0-6,3/NHI11 EAN 4015080394259 Product Length/Depth 76 mm Product Height 93 mm Product
- Manufacturer summary: Motor-protective circuit-breaker, 3p+1N/O+1N/C, Ir=4-6.3A, screw connection Switch motor protector; 3 pole + 1 NO + 1 NC; Ir=4-6.3 A; Connection to screw Eaton Moeller series PKZM0 Motor-protective circuit-breaker, 3p+1
More info
▲General specifications
UL
CSA
IEC/EN 60947
UL File No.: E36332
CSA File No.: 165628
CSA Class No.: 3211-05
CE
UL Category Control No.: NLRV
IEC/EN 60947-4-1
CSA-C22.2 No. 60947-4-1-14
UL 60947-4-1
Features & Functions
Phase failure sensitive
General
Branch circuit: Manual type E if used with terminal, or suitable for group installations, (UL/CSA)
-25 - 55 °C, Operating range
≤ 0.25 %/K, residual error for T > 40°
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 1.5) mm²
2 x (0.75 - 2.5) mm², Control circuit cables
18 - 10
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
50 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB, SCCR (UL/CSA)
50 kA, 600 Y/347 V, SCCR (UL/CSA)
Accessories required BK25/3-PKZ0-E
65 kA, 240 V, SCCR (UL/CSA)
± 20% tolerance, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks