Eaton Moeller PKZM0-32/AK motor-protective circuit-breaker provides robust thermal and magnetic protection for medium-duty industrial electric motors. It is frequently deployed in machine control panels to prevent motor damage caused by overloads, short circuits, or phase failures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 25 A
- Adjustment range undelayed short-circuit release (EF007131): 496 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 32 A
- Rated operation power at AC-3, 230 V (EF007025): 7.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 15 kW
- Power loss (EF005387): 9.56 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
CSA File No.: 165628
UL 60947-4-1
UL File No.: E36332
IEC/EN 60947
CSA-C22.2 No. 60947-4-1-14
UL
CE
IEC/EN 60947-4-1
VDE 0660
CSA Class No.: 3211-05
CSA
Features & Functions
Phase failure sensitive
General
Branch circuit: Suitable for group installations, (UL/CSA)
-5 - 40 °C to IEC/EN 60947, VDE 0660
≤ 0.25 %/K, residual error for T > 40°
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA)
18 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA)
18 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA)
18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA)
18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA)
Basic device fixed 15.5 x Iu, Trip Blocks
496 A, Irm, Setting range max.