View larger
PKZM0-2,5-SC/AK 265351 XTPRSC2P5BC1 EATON ELECTRIC Motor-Protective Circuit-Breakers, 3-pole, Ir 1.6 2.5 A, ..
PKZM0-2,5-SC/AK
265351
XTPRSC2P5BC1
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
PKZM0-2,5-SC/AK 265351 XTPRSC2P5BC1 EATON ELECTRIC Motor-Protective Circuit-Breakers, 3-pole, Ir 1.6 2.5 A, .. is a specialized motor-protective circuit breaker designed to monitor electrical loads and prevent motor damage caused by overloads or short circuits. Industrial control panels integrate these devices to protect driving equipment and ensure safe plant operations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 1.6 A
- Adjustment range undelayed short-circuit release (EF007131): 39 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 2.5 A
- Rated operation power at AC-3, 230 V (EF007025): 0.37 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.75 kW
- Power loss (EF005387): 5.16 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
VDE 0660
UL 60947-4-1
CSA File No.: 165628
IEC/EN 60947
CSA Class No.: 3211-05
CSA-C22.2 No. 60947-4-1-14
UL
CSA
IEC/EN 60947-4-1
UL Category Control No.: NLRV
CE
Features & Functions
Phase failure sensitive
General
Spring-cage terminals on output side
-25 - 55 °C, Operating range
-5 - 40 °C to IEC/EN 60947, VDE 0660
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.75 - 2.5) mm², ferrule to DIN 46228, Spring-loaded terminals
2 x (0.75 - 2.5) mm², ferrule to DIN 46228, Spring-loaded terminals
1 x (0.75 - 2.5) mm², without ferrule, Spring-loaded terminals
1 x (0.75 - 2.5) mm², Spring-loaded terminals
Electrical rating
Short-circuit rating
38.8 A, Irm, Setting range max.
± 20% tolerance, Trip blocks