View larger
PKZM0-1/AK 265335 Y7-265335 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 0.63-1A, thumb grip lock..
PKZM0-1/AK
265335
Y7-265335
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller PKZM0-1/AK 265335 Y7-265335 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 0.63-1A, thumb grip lock.. is installed within electrical enclosures to manage motor starts and protect connected assets from thermal overloads. It ensures operational safety by interrupting dangerous fault currents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0.63 A
- Adjustment range undelayed short-circuit release (EF007131): 15.5 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 1 A
- Rated operation power at AC-3, 230 V (EF007025): 0.12 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.25 kW
- Power loss (EF005387): 5.33 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
CSA Class No.: 3211-05
CSA-C22.2 No. 60947-4-1-14
UL 60947-4-1
UL File No.: E36332
UL Category Control No.: NLRV
CSA File No.: 165628
VDE 0660
CSA
IEC/EN 60947
UL
IEC/EN 60947-4-1
Features & Functions
Phase failure sensitive
General
Ex II (2) G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb]
Ex II (2) D [Ex tb Db] [Ex pxb Db]
Also motors with efficiency class IE3
-25 - 55 °C, Operating range
≤ 0.25 %/K, residual error for T > 40°
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
50 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB, SCCR (UL/CSA)
65 kA, 480 Y/277 V, SCCR (UL/CSA)
Accessories required BK25/3-PKZ0-E
50 kA, 600 Y/347 V, SCCR (UL/CSA)
15.5 A, Irm, Setting range max.
± 20% tolerance, Trip blocks