Request QuoteProduct Overview
The PKZM0-0,25/AK Eaton Moeller motor-protective circuit-breaker offers precise thermal and magnetic protection for low-amperage industrial electric motors. Motor protection switches are essential components in machinery control circuits, preventing overheating and mechanical damage during overcurrent conditions. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0.16 A
- Adjustment range undelayed short-circuit release (EF007131): 3.9 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 0.25 A
- Rated operation power at AC-3, 230 V (EF007025): 0 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.06 kW
- Power loss (EF005387): 5.15 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
IEC/EN 60947
CSA-C22.2 No. 60947-4-1-14
UL File No.: E36332
UL
VDE 0660
UL 60947-4-1
CSA Class No.: 3211-05
IEC/EN 60947-4-1
CE
CSA File No.: 165628
UL Category Control No.: NLRV
Features & Functions
Phase failure sensitive
General
Branch circuit: Manual type E if used with terminal, or suitable for group installations, (UL/CSA)
≤ 0.25 %/K, residual error for T > 40°
-25 - 55 °C, Operating range
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (1 - 6) mm², ferrule to DIN 46228
1 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
50 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB, SCCR (UL/CSA)
Accessories required BK25/3-PKZ0-E
65 kA, 240 V, SCCR (UL/CSA)
65 kA, 480 Y/277 V, SCCR (UL/CSA)
Basic device fixed 15.5 x Iu, Trip Blocks
3.9 A, Irm, Setting range max.