View larger
PKE65/AK/XTUW-32 158249 Y7-158249 EATON ELECTRIC Motor-protective circuit-breaker, 3p, +control option 8-32A
PKE65/AK/XTUW-32
158249
Y7-158249
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Motor-protective circuit-breaker, 3p, +control option 8-32A units like the Eaton Moeller PKE65/AK/XTUW-32 provide precise operational control and protection for three-phase electric motors against overcurrent, phase imbalance, and short circuits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 8 A
- Adjustment range undelayed short-circuit release (EF007131): 496 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 0 A
- Rated operation power at AC-3, 230 V (EF007025): 0 kW
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
IEC/EN 60947
UL File No.: E36332
IEC/EN 60947-4-1
CE
CSA Class No.: 3211-05
UL
CSA File No.: 165628
VDE 0660
CSA-C22.2 No. 60947-4-1-14
UL Category Control No.: NLRV
UL 60947-4-1
Features & Functions
Overload release
Motor protection
General
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
Note: Going below the minimum current flow time can cause overheating of the load (motor).
1000 (Class 20) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths
700 (Class 10) AC-4 cycle operation, Main conducting paths
Terminals: IP00
-25 - 55 °C, Operating range
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.75 - 35) mm², ferrule to DIN 46228
2 x (0.75 - 16) mm²
1 Nm, Screw terminals, Control circuit cables
Electrical rating
Short-circuit rating
200 A, Class J, 600 V High Fault, max. Fuse, SCCR (UL/CSA)
Delayed approx. 60 ms, Trip blocks
± 20% tolerance, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks
Switching capacity
32 A, General use UL/CSA