View larger
PKE32/XTU-36-SOND533 170128 XTPE036BCSNLSOND533 EATON ELECTRIC SOND Motor-protective circuit-breakers, 3-pol..
PKE32/XTU-36-SOND533
170128
Y7-170128
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller PKE32/XTU-36-SOND533 motor-protective circuit-breaker delivers advanced electronic trip intelligence to protect complex industrial drives and electrical systems against overloads. This specialty breaker ensures dependable system coordination and minimizes downtime across automated manufacturing lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 36 A
- Adjustment range undelayed short-circuit release (EF007131): 496 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 36 A
- Rated operation power at AC-3, 230 V (EF007025): 7.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 18.5 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
VDE 0660
Features & Functions
Phase failure sensitive
Overload release
Motor protection
General
1000 (Class 20) AC-4 cycle operation, Main conducting paths
Note: Going below the minimum current flow time can cause overheating of the load (motor).
500 (Class 5) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
700 (Class 10) AC-4 cycle operation, Main conducting paths
IP20
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (1 - 6) mm², ferrule to DIN 46228
2 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
Delayed approx. 60 ms, Trip blocks
Trip block fixed 496 A
± 20% tolerance, Trip blocks