View larger
PKE12/AK/XTU-1,2 158242 Y7-158242 EATON ELECTRIC Motor-protective circuit-breaker, 3p, +control, option 0.3-..
PKE12/AK/XTU-1,2
158242
Y7-158242
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for automated industrial systems, this Eaton Moeller PKE12/AK/XTU-1,2 Motor-protective circuit-breaker, 3p, +control, option 0.3-.. provides reliable switching and comprehensive fault protection for connected electric motors.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0.3 A
- Adjustment range undelayed short-circuit release (EF007131): 18.6 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 1.2 A
- Rated operation power at AC-3, 230 V (EF007025): 0.12 kW Rated operation power at AC-3, 400 V (EF001364): 0.25 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
IEC/EN 60947
IEC/EN 60947-4-1
UL
CE
CSA-C22.2 No. 60947-4-1-14
UL File No.: E36332
CSA
CSA Class No.: 3211-05
UL 60947-4-1
UL Category Control No.: NLRV
VDE 0660
Features & Functions
Motor protection
Phase failure sensitive
Overload release
General
500 (Class 5) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths
700 (Class 10) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
Note: Going below the minimum current flow time can cause overheating of the load (motor).
IP20
-5 - 40 °C to IEC/EN 60947, VDE 0660
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (1 - 6) mm², ferrule to DIN 46228
1 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
100 A, Class J, 600 V High Fault, max. Fuse, SCCR (UL/CSA)
Basic device fixed 15.5 x Iu, Trip Blocks
Delayed approx. 60 ms, Trip blocks
± 20% tolerance, Trip blocks