EATON - MOELLER EMR5-W500-1-D EMR5-W500-1-D 134221 EATON ELECTRIC Phase monitoring relay, over- undervoltage, 2W, 300-500V50/60Hz, tv 0.1-.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EMR5-W500-1-D 134221 EATON ELECTRIC Phase monitoring relay, over- undervoltage, 2W, 300-500V50/60Hz, tv 0.1-..

EMR5-W500-1-D

134221

EATON - MOELLER

1 Pcs.

Phase monitoring relay, over- undervoltage, 2W, 300-500V50/60Hz, tv=0.1-30s Phase monitoring relay; Over-Undervoltage; 2 W; 300-500 V 50/60 Hz; tv=0.1-30 s Phase monitoring relay EMR5-W… according to IEC/EN 60255-6, 22.5 mm wide, 300-500VAC, phase Sequence, phase failure, overVoltage, underVoltage, adjustable threshold values, response- / OFF-delay: none or 0.1 up to 30s

Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Fuse-base, low voltage, 160 A, AC 690 V, NH00, 1P, IEC
Fuse accessory, Fuse-base, low voltage, 160 A, AC 690 V, NH00, 1P, IEC, Breaking Capacity, Ceramic
[

Delivery program

Product range
Fuse accessory
Basic function
Fuse-base
Field of application
low voltage
Rated current [I]
160 A
Rated voltage
AC 690 V
Construction size
NH00
Number of poles
1P
Standard/Approval
IEC
Material
Ceramic
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Low Voltage HRC fuse base (EC000067)
Electric engineering, automation, process control engineering / Electrical installation, device / Safety fuse systems / Low-Voltage HRC fuse base ([email protected] [AKE278013])
Construction size
NH00
Number of poles
1
Rated current
160 A
Bus-mounting type
No
Swivelling mechanism
No
]

ETIM for 134221 Relays (EC001441)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
External power supply required (EF003292) No
Phase sequence monitoring (EF003412) Yes
Phase failure detection (EF003413) Yes
Function under voltage detection (EF003414) Yes
Function over voltage detection (EF003415) Yes
Phase imbalance monitoring (EF003416) No
Voltage measuring range (EF002486) 300 V
Min. adjustable delay-on energization time (EF008190) 0.1 s
Max. permitted delay-on energization time (EF008189) 30 s
Min. adjustable off-delay time (EF008192) 0.1 s
Max. permitted off-delay time (EF008191) 30 s
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 0
Width (EF000008) 23 mm
Height (EF000040) 100 mm
Depth (EF000049) 78 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.