EATON - MOELLER EMR5-AWN170-1-E EMR5-AWN170-1-E 134225 EATON ELECTRIC Phase monitoring relay, multi-function, 2W, 90-170V50/60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EMR5-AWN170-1-E 134225 EATON ELECTRIC Phase monitoring relay, multi-function, 2W, 90-170V50/60Hz

EMR5-AWN170-1-E

134225

EATON - MOELLER

1 Pcs.

Phase monitoring relay, multi-function, 2W, 90-170V50/60Hz Relay for monitoring phase; Multi-Function; 2 W; 90-170 V 50/60 Hz Phase monitoring relay EMR5-AWN… according to IEC/EN 60255-6, 22.5 mm wide, 90-170VAC, 50/60/400Hz, phase Sequence, phase failure, overVoltage, underVoltage, imbalance, neutral cable break, adjustable threshold values, response- / OFF-delay: none or 0.1 up to 30s

Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Fuse-base, LV, 63 A, AC 400 V, D02, 1P, IEC, DIN rail mount, suitable wire 2.5 - 25 mm2, 2xM5 o/p terminals, M6 i/p terminal
Fuse accessory, Fuse-base, LV, 63 A, AC 400 V, D02, 1P, IEC, DIN rail mount, suitable wire 2.5 - 25 mm2, 2xM5 o/p terminals, M6 i/p terminal
[

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / D0-system fuse base (EC001644)
Electric engineering, automation, process control engineering / Electrical installation, device / Safety fuse systems / Neozed fuse base ([email protected] [ACN355011])
Number of poles
1
Construction size
D02
Material
Porcelain
Version with cover
Yes
Mounting method
DIN rail
Rated voltage
400 V
Rated current
63 A
]

ETIM for 134225 Relays (EC001441)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
External power supply required (EF003292) No
Phase sequence monitoring (EF003412) Yes
Phase failure detection (EF003413) Yes
Function under voltage detection (EF003414) Yes
Function over voltage detection (EF003415) Yes
Phase imbalance monitoring (EF003416) Yes
Voltage measuring range (EF002486) 0 V
Min. adjustable delay-on energization time (EF008190) 0.1 s
Max. permitted delay-on energization time (EF008189) 30 s
Min. adjustable off-delay time (EF008192) 0.1 s
Max. permitted off-delay time (EF008191) 30 s
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Width (EF000008) 23 mm
Height (EF000040) 100 mm
Depth (EF000049) 78 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.