Phase imbalance monitoring relay, 2W, 300-500V/50/60Hz, tv=0.1-30s Relay for monitoring phase imbalance; 2 W; 300-500V/50/60 Hz; tv=0.1-30 s Phase imbalance monitoring relay EMR5-A… according to IEC/EN 60255-6, 22.5 mm wide, 300-500VAC, phase Sequence, phase failure, imbalance (adjustable threshold values 2-25%), response delay: none or adjustable from 0.1 to 30 s

Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The EMR5-A400-1 Eaton Moeller phase imbalance monitoring relay is built to supervise three-phase supply lines for voltage asymmetries and missing phases that can threaten connected assets. Facilities rely on this protection equipment to maintain balanced loads and prevent overheating in industrial machinery.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Screw connection
  • With detachable clamps (EF003340): No
  • External power supply required (EF003292): No
  • Phase sequence monitoring (EF003412): Yes
  • Phase failure detection (EF003413): Yes
  • Function under voltage detection (EF003414): No
  • Function over voltage detection (EF003415): No
  • Phase imbalance monitoring (EF003416): Yes
  • Voltage measuring range (EF002486): 300 V
  • Min. adjustable delay-on energization time (EF008190): 0.1 s
  • Max. permitted delay-on energization time (EF008189): 30 s
  • Min. adjustable off-delay time (EF008192): 0.1 s
  • Max. permitted off-delay time (EF008191): 30 s
  • Number of contacts as normally closed contact (EF008255): 0
  • Number of contacts as normally open contact (EF008256): 0
  • Number of contacts as change-over contact (EF008257): 0

More info

▲
Fuse-link, low voltage, 1.5 A, AC 250 V, 10 x 38 mm, supplemental, UL, CSA, time-delay
Fuse, Fuse-link, low voltage, 1.5 A, AC 250 V, 10 x 38 mm, supplemental, UL, CSA, time-delay, cylindrical, colour-coded, green, general purpose, lighting circuits, meter circuits, UL 248-14, melamine tube
[

Delivery program

Product range
Fuse
Basic function
Fuse-link
Field of application
low voltage
Rated current [I]
1.5 A
Rated voltage
AC 250 V
Size
10 x 38 mm
Utilization category
supplemental
Description
colour-coded
green
usable for size/applications
general purpose, lighting circuits, meter circuits
Release characteristic [class]
time-delay
Standard/Approval
UL
CSA
Shape
cylindrical
Material
melamine tube
Standards/Regulations
UL 248-14
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Cylindrical fuse (EC002704)
Electric engineering, automation, process control engineering / Electrical installation, device / Safety fuse inserts / Cylindrical fuse (safety fuse) ([email protected] [AFZ797013])
Size
10x38 mm
Rated voltage
250 - 250 V
Rated voltage
Other
Voltage type
AC
Utilization category
Other
Rated operating frequency
45 - 62 Hz
Nominal current
1.5 A
With striker
No
Release characteristic
M (Midget)
Breaking capacity
0.1 kA
]

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.