PFIM-100/4/03-G/A 102873 Y7-102873 EATON ELECTRIC Residual current circuit breaker (RCCB), 100A, 4p, 300mA, ..
PFIM-100/4/03-G/A
102873
Y7-102873
EATON - MOELLER
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Protection against ground faults and insulation failures in industrial electrical distribution systems is achieved using a residual current circuit breaker (RCCB), such as the Eaton Moeller PFIM-100/4/03-G/A 102873 Y7-102873 EATON ELECTRIC. The component monitors incoming and outgoing current paths to trip circuits instantly when dangerous leakage currents are detected, safeguarding operators and downstream machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Rated voltage (EF000228): 400 V
- Rated current (EF000227): 100 A
- Rated fault current (EF002358): 0.3 A
- Rated insulation voltage Ui (EF001366): 440 V
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
- Mounting method (EF000003): DIN rail
- Leakage current type (EF002560): A
- Selective protection (EF002561): No
- Short-time delayed tripping (EF003604): Yes
- Short-circuit breaking capacity (Icw) (EF002562): 10 kA
- Surge current capacity (EF002564): 3 kA
- Voltage type (EF000187): AC
- With interlocking device (EF007385): Yes
- Frequency (EF005455): 50 Hz
- Additional equipment possible (EF008148): Yes
More info
▲General specifications
ÖVE E 8601
Delivery program
- PFIM
- Residual current circuit breakers
- Type G/A (ÖVE E 8601)
Technical data - electrical
Technical data - mechanical
Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
IP20, IP40 with suitable enclosure
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Residual current circuit breaker
- Maximum operating temperature is 60 °C: Starting at 40 °C, the max. permissible continuous current decreases by 1.2% for every 1 °C
- Tripping signal contact for subsequent installation Z-NHK 248434
Residual current circuit breakers
KLV-TC-2 276240 (Compact enclosure)
Z-FW/LP 248296 (Remote control and automatic switching device)
Z-RC/AK-4MU 101062 (sealing cover set)